Description
FREE SHIPPING INCLUDED
This kit includes:
- SureBP Non-invasive Blood Pressure
Designed with Patient Outcomes in Mind
- Quickly and securely access a device with single sign-on (including Imprivata integration)
- Measure blood pressure in just 15 seconds with SureBP technology
- Help ensure accurate hypertension detection with BP averaging
- Connect to your EMR with WiFi, Ethernet, Bluetooth or Bluetooth Low Energy
- Enter height, weight and BMI with Scale-Tronix, Detecto, Health o meter or SECA scales
- Help identify signs of patient deterioration with automated Early Warning Scores
- Customize your workflow to document patient observations and vitals modifiers
- Meet your workflow needs with mobile stands, wall mounts and integrated exam systems
- Secure patient information with data encryption and additional security features specified by the U.S. Department of Defense (DoD)
TECHNICAL INFO
NONINVASIVE BLOOD PRESSURE (NIBP)
Cuff Inflation Target Adult: 160 mmHg Pediatric: 140 mmHg Neonate: 90 mmHg
Systolic Range Adult/Pediatric: 30 – 260 mmHg Neonate: 20 – 120 mmHg
Diastolic Range Adult/Pediatric: 20 – 220 mmHg Neonate: 10 – 110 mmHg
MAP Range Adult/Pediatric: 23 – 230 mmHg Neonate: 13 – 110 mmHg
Blood Pressure Accuracy Meets the ANSI/AAMI SP10: 2002 and ISO/ANSI/AAMI 81060-2:2013 standards for noninvasive blood pressure accuracy (±5 mmHg mean error, 8 mmHg SD)
BP Determination Time: 15 seconds typical, 150 seconds max
Overpressure Cutoff Adult/Pediatric: 300 mmHg ± 15 mmHg Neonate: 150 mmHg maximum
Pulse Rate Range Adult/Pediatric: 30 – 200 bpm Neonate: 35 – 220 bpm
Pulse Rate Accuracy ± 5.0% (±3 bpm)
Temperature
Measurement Range SureTemp® Plus: 80 - 110°F (26.7 – 43.3°C) Braun: 68 - 108°F (20 – 42.2°C)
Calibration Accuracy SureTemp Plus: ±0.2°F (±0.1°C) Braun: ±0.4°F (for temps up to 107.6°F), ±0.5°F (for temps higher than 107.6°F)
Determination Time Oral: Approximately 4-6 seconds Adult Axillary (18 years and older): Approximately 15 seconds Pediatric Axillary (17 years and younger): Approximately 10 seconds Rectal: Approximately 10 seconds Tympanic: Approximately 3 seconds
SPO2
Measurement Range : 1-100%
Pulse Rate Range :Masimo: 25 – 240 bpm Nellcor: 25 – 240 bpm Nonin: 40 – 240 bpm
SpO2 Accuracy: Masimo: ± 2 digits Nellcor: ± 3 digits Nonin: ± 3 digits
Pulse Rate Accuracy: Masimo: ± 3 digits Nellcor: ± 3 digits Nonin: ± 3 digits
MECHANICAL
Dimensions: Height: 6.3 in (16.1 cm) Width: 9.2 in (23.4 cm) Depth: 2.3 in (5.8 cm)
Weight: 2.9 lbs (1.3 kg)
ENVIRONMENTAL
Operating Temperature: 50 – 104°F (10 – 40°C)
Storage Temperature:-4 – 122°F (-20 – 50°C)
Operating Altitude: -1250 – 10,000 ft. (-381 – 3,048 m)
Operating Humidity: 15% to 90% noncondensing
Storage Humidity: 15% to 95% noncondensing
EMC Standard: IEC/EN 60601-1-2
ELECTRICAL
AC Power Supply: 15V at 2.33A
Operating Time (Integrated 2-Cell Battery): Up to 12 hours with fully charged battery
Battery Recharge Time: 4 hours
Operating Time (APM with 9-Cell Battery): Up to 17 hours
WIRELESS RADIO
Wireless Network Interface: IEEE 802.11 a/b/g/n
Frequency: 2.4 GHz – 2.483 GHz (2.4 GHz bands) 5.15 GHz to 5.35 GHz, 5.725 GHz to 5.825 GHz (5 GHz bands)
Authentication/Encryption: Wireless Equivalent Privacy (WEP, RC4 Algorithm); Wi-Fi Protected Access (WPA); IEEE 802.11i (WPA2); TKIP, RC4 Algorithm; AES, Rijndael Algorithm; Encryption Key Provisioning; Static (40-bit and 128-bit lengths); PSK; Dynamic; EAP-FAST; EAP-TLS; EAP-TTLS; PEAP-GTC 1 PEAPMSCHAPv2; PEAP-TLS
FIPS 140-2: Yes
Device Data Security Features: FIPS-approved encryption algorithms of transmitted data; Server authentication of the device; Digitally signed software images and configuration files
Warranty
Manufacturer 2 year warranty on this item. Please click here for more information.
Shipping
Shipping is included.