Description
The Edan SE-1202 is a 12-channel ECG machine with a user-friendly 10.1" touchscreen and systems designed to simplify the process of capturing and analyzing heart activity. The modern glass surface is easy to clean and promotes infection control.
Features
- All-in-One workstation enables paperless workflow with all measurements & diagnosis on screen
- 10.1" Touchscreen folds up for comfortable operation
- Waterproof keys and screen facilitates easy cleaning and sterilization
- Capable of long-time sampling to assist with pre-treatment diagnosis or post-treatment evaluations (1800 seconds)
- 12-lead standard resting ECG
- 9-lead resting ECG tailored for neonates
- Innovative color visualization for lead placement detection enhances ECG accuracy
- Auto Arrhythmia detection highlights trace segments on display with autosaving strips
- ST-View function displays ST segments helping doctors locate the accurate MI position & make diagnosis
- Waveform segments can be amplified and measured on screen
- Pacemaker Detection
- Glasgow Interpretation
- Select and compare reports
- 1000 ECG Test Storage
- USB file export for PDF, JPG, FDA, XML
- Connect to hospital systems with HL7 and DICOM protocols via LAN/WIFI/4G
- 2 Year Warranty
Advanced Clinical Tools
- Vector ECG & Timed Vector ECG (VCG & TVCG)
- Heart Rate Variability (HRV) analysis
- Pharmacological Study
- Signal-average ECG (SAECG)
What's in the Box
- SE-1202 ECG Workstation
- ECG Cable (4mm banana connector)
- Resting Tab Electrodes (100 count)
- 10-Lead Universal Clips
- Z-fold Recording Paper (100 pages)
- Power Cord (USA)
- Rechargeable Battery (2200mAH)
- User Manual & Docs
Specs
Technical Specs
Physical Specs | |
---|---|
Dimensions | 400mm x 360mm x 90mm |
Weight | 14.3lbs / 6.5kg (excluding recorder paper & battery) |
Display | |
Display | 10.1" 1280x800 multicolor LCD touch screen |
Power | |
Power Supply | Operating Voltage = 100V-240V Operating Frequency = 50Hz/60Hz Input Current = 0.9-0.4A |
Li-ion Battery Pack | Rated Capacity = 2500mAh Charge Time = 3 hrs |
Recording | |
Recorder | Thermal dot-matrix recorder |
Printing Density | 8 dots per mm / 200 dots per inch (amplitude axes) 40 dos per mm / 1000 dots per inch (time axes, @ 25 mm/s) |
Recorder Paper | Folded thermal paper: 210mm x 295mm x 100pages Folded thermal paper: 215mm x 280mm x 100pages Folded thermal paper: 210mm x 295mm x 200pages |
Paper Speed | 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s |
HR | |
HR Range | 30 BPM ~300 BPM |
Accuracy | ±1 BPM |
ECG | |
Leads | 9 or 12 standard leads |
Acquisition Mode | Simultaneously 9 or 12 leads |
Sampling Frequency | 64,000/sec/channel |
A/D Converter | 24 bits |
Resolution | 0.1192 μV/LSB |
Time Constant | ≥5s |
Frequency Response | 0.01Hz ~ 350Hz (-3dB) |
Gain | 1.25 mm/mV, 2.5 mm/mV, 5mm/mV, 10 mm/mV, 20mm/mV, 10/5 mm/mV, AGC (mm/mV) (±5%) |
Input Impedance | ≥100MΩ (10Hz) |
Input Circuit Current | ≤0.01μA |
Input Voltage Range | ≤±5 mVpp |
Calibration Voltage | 1mV±2% |
DC Offset Voltage | ±900 mV, ±5% |
Minimum Amplitude | 20 μVp-p (10Hz) |
Noise | ≤12.5 μVp-p |
Multichannel crosstalk | ≤0.5 mm |
Pacemaker Detection | |
Amplitude | ±500μV to ±700mV |
Width | 30μs to 2.0ms |
Sampling Frequency | 80,000 /sec/channel, Rhythm Lead |
Filter | |
AC Filter | 50/60Hz |
DFT Filter | 0.01Hz/0.05Hz/0.32Hz/0.67Hz |
EMG Filter | Off/25Hz/35Hz/45Hz |
LOWPASS Filter | 300Hz/270Hz/150Hz/100Hz/75Hz |
Data Transmission | |
Report Format | DAT, PDF, JPG, BMP, TIFF, SCP, FDA, XML, DICOM ECG Waveform, DICOM Encapsulated PDF |
Data Transmission | Wi-Fi, Ethernet, 4G |
HIS connection | DICOM Worklist/DICOM Storage/HL7 |
Data Storage | 1,000 ECGs |
Wifi | |
Radio | 802.11 a/b/g/n |
Bandwidth | 2.4 GHz & 5 GHz |
Environment Specs | |
Temperature | Transport & Storage: -20ºC (-4ºF) ~ +55ºC (+131ºF) Working: +5ºC (+41ºF) ~ +40ºC (+104ºF) |
Relative Humidity | Transport & Storage: 15%~95% Non-Condensing Working: 15%~95% Non-Condensing |
Atmospheric Pressure | Transport & Storage: 70kPa ~106kPa Working: 70kPa ~106kPa |